With Viking, you can have professional-quality refrigeration systems in the comfort of your own residence. It makes sense that you wouldn’t want to trust your financial investment to just any appliance repair service business. That’s why you ought to call the Viking refrigerator fixing specialists.
We offer superior Viking refrigerator repair work solution 7 days a week. Our specialists are on phone call everywhere near your area. When you require superior assistance for your costs fridge, call us.
The control unit of your Viking fridge monitors the important parts of the device. If a mistake is identified, the electronic screen provides an error code to aid find as well as repair the problem.
The primary step to solving any problem is to validate the error is legitimate. To verify a mistake code, you will certainly require to reboot the fridge.
To reboot your refrigerator:
Unplug the refrigerator from the wall or turn off power to the electrical outlet at the circuit breaker.
Wait 5 minutes.
Return power to the refrigerator.
If the mistake code returns, it is a reputable mistake. Refer to the adhering to graph for more repairing support.
Error Code Detection
The microprocessor in the control continuously checks crucial refrigeration system parts for proper operation. If part criteria exceed regular operating specifications, an audible alarm system will seem six (6) times every minute as well as the display screen will immediately flash the particular error code. If several errors are noted with the unit, the error codes will be presented sequentially.
Caution Alarm system
The Tru Protect ™ system will certainly educate you if the device is not operating correctly. It gives both aesthetic and distinct signals if the temperature level rises above or drops below the set temperature level, if there is a power failing, or if the door is left open.
- Door Ajar: If the door is exposed for more than 5 (5) minutes, an audible alarm system will certainly sound 3 (3) times every 30 secs and also the LED light will certainly flash eco-friendly. This will stop as quickly as the door is closed.
- Low And High Temperature: If the system gets to a temperature either above or listed below the collection factor temperature level for more than one (1) hour, an audible alarm will certainly sound six (6) times every min as well as the LED will flash red. This will proceed till the alarm is reset. The alarm may occur when altering set-points over of 10 degrees F and/or high usage which is typical.
- Power Failure: If the unit experiences a power failure, the LED will certainly blink brownish-yellow. This will continue up until the alarm system is reset. With a power failing, no distinct signal is heard. The alarm system may occur upon preliminary installation which is normal given that the unit was gone for the manufacturing facility to verify quality.
Resetting the Alarms
Close door to reset Door Open alarm. Press the “ON/OFF” switch for approximately one (1) second to reset all various other audible and also display alarms.
KEEP IN MIND: Although pressing the “ON/OFF” button will reset the alarm systems, the alarm will certainly resume if the “alarm system problem” still exists.
Service Diagnostics Mode
Service Diagnostics Mode permits you to identify the firmware and software program versions, test standing of “model certain” system components as well as sensing units, and also transform state of parts where relevant (i.e.– compressor on/off, and so on.).
ERROR CODE | CAUSE | SOLUTION |
Eu | Failed upper zone temperature sensor | It will be necessary to locate and replace the failed part. |