With Viking, you can have professional-quality refrigeration systems in the convenience of your own residence. It makes sense that you would not wish to trust your financial investment to just any kind of appliance repair service firm. That’s why you must call the Viking fridge repair specialists.
We offer superior Viking refrigerator fixing service seven days a week. Our specialists get on call anywhere near your location. When you need exceptional support for your premium fridge, call us.
The control system of your Viking refrigerator monitors the important parts of the device. If a mistake is found, the electronic display provides a mistake code to help situate and also repair the concern.
The first step to resolving any issue is to confirm the mistake is genuine. To verify a mistake code, you will need to reboot the refrigerator.
To reboot your fridge:
Disconnect the fridge from the wall or turn off power to the electrical outlet at the breaker.
Wait 5 minutes.
Return power to the fridge.
If the mistake code returns, it is a legit error. Refer to the complying with graph for further repairing aid.
Error Code Discovery
The microprocessor in the control consistently keeps track of crucial refrigeration system parts for correct operation. If element parameters surpass regular operating requirements, an audible alarm will certainly seem six (6) times every min as well as the display screen will immediately flash the respective mistake code. If several mistakes are kept in mind with the device, the mistake codes will certainly be presented sequentially.
Caution Alarm
The Tru Protect ™ system will inform you if the unit is not functioning appropriately. It gives both visual and distinct notifies if the temperature level rises above or drops below the set temperature, if there is a power failure, or if the door is left open.
- Door Ajar: If the door is exposed for greater than 5 (5) minutes, a distinct alarm will seem three (3) times every 30 secs and also the LED light will blink green. This will certainly stop as quickly as the door is shut.
- Low And High Temperature Level: If the unit gets to a temperature either above or below the collection factor temperature level for more than one (1) hr, an audible alarm system will certainly sound 6 (6) times every minute as well as the LED will blink red. This will certainly continue up until the alarm system is reset. The alarm system might occur when transforming set-points over of 10 degrees F and/or high use which is normal.
- Power Failure: If the system experiences a power failure, the LED will certainly blink amber. This will continue until the alarm is reset. With a power failing, no audible signal is heard. The alarm system may happen upon initial installation which is normal given that the unit was gone for the manufacturing facility to validate top quality.
Resetting the Alarms
Close door to reset Door Open alarm. Press the “ON/OFF” button for roughly one (1) second to reset all other distinct as well as display alarm systems.
KEEP IN MIND: Although pressing the “ON/OFF” switch will certainly reset the alarm systems, the alarm system will certainly resume if the “alarm problem” still exists.
Solution Diagnostics Setting
Solution Diagnostics Setting enables you to identify the firmware and also software application variations, examination condition of “version details” system elements and sensors, and also transform state of parts where applicable (i.e.– compressor on/off, etc.).
ERROR CODE | CAUSE | SOLUTION |
E3 | A fault with the evaporator thermistor has been detected. | This error may be caused by disconnected wiring, shorted wires, or a faulty thermistor. It is necessary to test all connections and the affected parts to repair the issue. |