Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Info
Service Diagnostics Setting permits you to recognize the firmware and also software variations, examination condition of “design certain” system elements and also sensors, and alter state of parts where appropriate (i.e.– compressor on/off, etc.).
Enabling Solution Mode: To enable Solution Setting, press as well as hold the “WARMER” button while pressing the “COLDER” button 4 times within five secs.
- You can not enable Solution Setting while in Establish Setting. – All system features will certainly remain in their present state while in Service Mode.
- Alarm systems are disabled during Service Mode as well as reset after exiting Solution Setting.
- Solution Setting will instantly disable after five (5) mins of no keypad entrance
After going into Service Setting, the first number that you will see suggests the software application version number for the particular unit you are servicing. For instance, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the first number you will see is 11. See graph listed below for matching design and also software program referral.
The 2nd number you will see shows the software application variation launch. For example, if you see 44 on the screen panel it shows software program version 4.4.
Diagnostics:
While in Service Mode, press the “COLLECTION” switch to tip through Tests 0-9. The initial digit of the display screen will reveal the examination number. The 2nd number suggests the current state of each component under test and also is presented as “1” being ON, CLOSED, or SHORTED and also “0” being OFF or OPEN. Examinations 0 as well as 1 disclose an open or shorted problem identified at the sensor inputs. Examinations 2 via 6 enable you to turn lots ON with the “WARMER” button and also OFF with the “COLDER” switch. Examinations 7 via 9 validate state modification of the door switches and/or magnetic reed sensor. The component examinations readily available are defined in Readily available Part Examinations chart.
SOUND | POSSIBLE CAUSE | SOLUTION |
Buzzing | Ice maker water valve hookup buzzes when ice maker fills with water. | Normal operation |