Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Details
Solution Diagnostics Mode enables you to recognize the firmware as well as software program versions, examination standing of “design certain” system parts and also sensors, and change state of elements where relevant (i.e.– compressor on/off, etc.).
Enabling Solution Setting: To enable Solution Mode, press and hold the “WARMER” switch while pressing the “COLDER” switch 4 times within 5 secs.
- You can not allow Service Mode while in Establish Setting. – All system features will certainly stay in their present state while in Service Mode.
- Alarm systems are handicapped during Service Setting as well as reset after leaving Service Setting.
- Service Mode will instantly disable after 5 (5) minutes of no keypad access
After going into Service Setting, the first number that you will see suggests the software program version number for the particular system you are servicing. For instance, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the very first number you will see is 11. See graph below for equivalent version as well as software referral.
The second number you will certainly see shows the software application version release. For instance, if you see 44 on the display screen panel it shows software variation 4.4.
Diagnostics:
While in Service Mode, press the “COLLECTION” switch to tip through Tests 0-9. The very first figure of the display screen will show the test number. The 2nd number suggests the present state of each component under test and also is displayed as “1” being ON, CLOSED, or SHORTED as well as “0” being OFF or OPEN. Examinations 0 and also 1 disclose an open or shorted problem spotted at the sensing unit inputs. Examinations 2 with 6 permit you to turn lots ON with the “WARMER” button and OFF with the “COLDER” switch. Examinations 7 via 9 validate state change of the door switches over and/or magnetic reed sensor. The element examinations readily available are defined in Available Component Examinations chart.
SOUND | POSSIBLE CAUSE | SOLUTION |
Vibrating noise | Compressor makes a pulsating sound while running | Normal operation |
Refrigerator is not level | See Installation Instructions for details on how to level your refrigerator. |