Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Details
Solution Diagnostics Setting permits you to determine the firmware and also software program versions, examination status of “version certain” system elements as well as sensors, and also change state of parts where relevant (i.e.– compressor on/off, etc.).
Enabling Service Setting: To allow Service Mode, press and also hold the “WARMER” switch while pressing the “COLDER” button four times within 5 seconds.
- You can not enable Solution Mode while in Establish Setting. – All system features will certainly remain in their existing state while in Service Setting.
- Alarm systems are disabled during Solution Setting as well as reset after leaving Solution Setting.
- Solution Setting will automatically disable after five (5) mins of no keypad access
After getting in Service Mode, the initial number that you will certainly see indicates the software program design number for the particular unit you are servicing. For instance, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the first number you will see is 11. See chart below for equivalent version and software referral.
The second number you will certainly see suggests the software version release. As an example, if you see 44 on the screen panel it suggests software application version 4.4.
Diagnostics:
While in Service Mode, press the “COLLECTION” button to tip with Examinations 0-9. The initial digit of the display screen will show the test number. The second number indicates the present state of each element under test as well as is shown as “1” getting on, CLOSED, or SHORTED and “0” being OFF or OPEN. Examinations 0 and also 1 reveal an open or shorted problem discovered at the sensing unit inputs. Tests 2 through 6 allow you to turn lots ON with the “WARMER” switch and OFF with the “COLDER” switch. Tests 7 via 9 validate state change of the door switches and/or magnetic reed sensor. The element examinations readily available are explained in Available Component Tests graph.
SOUND | POSSIBLE CAUSE | SOLUTION |
Clicking | Freezer control clicks when starting or stopping compressor. | Normal operation |