Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Information
Solution Diagnostics Mode enables you to determine the firmware and also software program versions, examination condition of “design certain” system components and sensors, as well as transform state of parts where relevant (i.e.– compressor on/off, etc.).
Enabling Solution Mode: To make it possible for Service Setting, press and also hold the “WARMER” button while pressing the “COLDER” switch 4 times within 5 seconds.
- You can not allow Solution Setting while in Set Setting. – All system features will stay in their current state while in Service Setting.
- Alarms are handicapped throughout Solution Setting as well as reset after exiting Solution Setting.
- Service Setting will immediately disable after five (5) mins of no keypad entry
After getting in Service Mode, the very first number that you will certainly see suggests the software program design number for the particular system you are servicing. For example, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the first number you will see is 11. See graph below for equivalent model and also software program recommendation.
The 2nd number you will see indicates the software application variation release. For example, if you see 44 on the screen panel it suggests software program variation 4.4.
Diagnostics:
While in Service Mode, press the “SET” button to tip through Examinations 0-9. The very first number of the display screen will certainly show the test number. The 2nd figure suggests the present state of each component under test as well as is shown as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Examinations 0 and 1 expose an open or shorted problem spotted at the sensor inputs. Tests 2 through 6 permit you to turn tons ON with the “WARMER” switch and also OFF with the “COLDER” switch. Tests 7 with 9 verify state modification of the door switches and/or magnetic reed sensor. The element examinations available are described in Offered Component Tests graph.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Water droplets form inside of refrigerator | Humidity levels are high or door has been opened frequently | Properly adjust controls Reduce time door is open Organize food items efficiently to assure door is open for shortest time. |