Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Info
Service Diagnostics Mode enables you to determine the firmware and also software versions, test standing of “model particular” system elements and sensors, as well as transform state of parts where applicable (i.e.– compressor on/off, etc.).
Enabling Service Mode: To allow Service Mode, press and hold the “WARMER” switch while pressing the “COLDER” button four times within five secs.
- You can not make it possible for Service Mode while in Set Mode. – All system functions will stay in their current state while in Service Setting.
- Alarm systems are impaired throughout Solution Mode and also reset after exiting Service Setting.
- Solution Setting will immediately disable after 5 (5) mins of no keypad access
After going into Solution Mode, the initial number that you will see shows the software application design number for the particular unit you are servicing. As an example, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the initial number you will see is 11. See graph listed below for equivalent design and also software program recommendation.
The 2nd number you will certainly see shows the software variation release. For instance, if you see 44 on the display panel it indicates software version 4.4.
Diagnostics:
While in Service Setting, press the “SET” button to tip through Tests 0-9. The first number of the screen will certainly show the test number. The second figure indicates the current state of each element under examination and is displayed as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Examinations 0 as well as 1 expose an open or shorted condition spotted at the sensing unit inputs. Examinations 2 with 6 permit you to turn lots ON with the “WARMER” switch and also OFF with the “COLDER” switch. Tests 7 through 9 confirm state modification of the door switches and/or magnetic reed sensing unit. The element tests offered are explained in Offered Component Tests chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Refrigerator does not operate | Refrigerator is not plugged in | Plug in refrigerator. |
Control is not on Fuse is blown, or circuit breaker needs to be reset | Properly adjust controls Replace blown fuses. Check circuit breaker and reset. | |
Power outage has occurred. | Call local power company to report outage |