Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Info
Service Diagnostics Mode permits you to recognize the firmware and software variations, examination standing of “design certain” system parts and sensors, as well as change state of components where applicable (i.e.– compressor on/off, and so on.).
Enabling Solution Mode: To allow Service Setting, press and also hold the “WARMER” button while pressing the “COLDER” button 4 times within 5 secs.
- You can not make it possible for Service Setting while in Establish Mode. – All system features will continue to be in their present state while in Service Setting.
- Alarm systems are handicapped throughout Solution Mode and also reset after exiting Service Setting.
- Service Mode will immediately disable after five (5) mins of no keypad entry
After getting in Service Mode, the very first number that you will see shows the software application model number for the particular system you are servicing. For example, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the first number you will certainly see is 11. See graph listed below for matching model as well as software application referral.
The 2nd number you will see indicates the software program version release. For example, if you see 44 on the screen panel it suggests software variation 4.4.
Diagnostics:
While in Service Setting, press the “SET” button to step via Tests 0-9. The initial figure of the display screen will certainly reveal the test number. The 2nd digit shows the current state of each component under test as well as is displayed as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Tests 0 as well as 1 reveal an open or shorted condition found at the sensing unit inputs. Examinations 2 via 6 enable you to turn loads ON with the “WARMER” switch as well as OFF with the “COLDER” switch. Examinations 7 through 9 validate state modification of the door switches and/or magnetic reed sensor. The element examinations offered are explained in Readily available Element Examinations chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
MeatSavor drawer temperature is too warm | Control settings are too low. | See p 5 to properly adjust controls. |