Viking Fridge Problem 13 – How to fix? by ApplianceRepairNewYork.us

Software Model Number

ModelDescriptionSoftware Model Number
DFUW, DUWC, VUWC24 inch Wine Cellar11
DFUR, DUAR, VUAR24 inch Beverage Center21
DFRD, DURD, VURD24 inch Refrigerated Drawers16
Viking Refrigerator Common Problems

Viking Refrigerator Diagnostic Details

Solution Diagnostics Setting enables you to determine the firmware and software application versions, examination condition of “model certain” system components and sensors, and change state of elements where suitable (i.e.– compressor on/off, etc.).

Enabling Service Setting: To make it possible for Solution Mode, press and hold the “WARMER” button while pressing the “COLDER” button four times within 5 secs.

  • You can not enable Service Mode while in Establish Mode. – All system features will certainly continue to be in their current state while in Service Setting.
  • Alarm systems are disabled during Solution Mode as well as reset after exiting Solution Setting.
  • Solution Setting will immediately disable after five (5) minutes of no keypad entrance

After going into Service Setting, the initial number that you will certainly see shows the software model number for the particular device you are servicing. For instance, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the initial number you will see is 11. See graph listed below for corresponding model and software referral.

The second number you will certainly see shows the software variation launch. For example, if you see 44 on the display panel it indicates software variation 4.4.

Diagnostics:
While in Service Setting, press the “COLLECTION” switch to tip with Tests 0-9. The very first figure of the display will show the examination number. The second digit suggests the current state of each component under examination as well as is displayed as “1” getting on, CLOSED, or SHORTED and “0” being OFF or OPEN. Tests 0 and 1 disclose an open or shorted problem spotted at the sensing unit inputs. Examinations 2 with 6 enable you to turn loads ON with the “WARMER” button and also OFF with the “COLDER” switch. Tests 7 with 9 confirm state adjustment of the door changes and/or magnetic reed sensing unit. The element examinations available are described in Readily available Component Examinations chart.

PROBLEMPOSSIBLE CAUSEWHAT TO DO
Ice forms in inlet tube to ice makerWater pressure is lowWater pressure is low between 35 – 100 pounds per square inch. A
minimum pressure of 35 pounds per square inch is recommended for
refrigerators with water filters.
Freezer temperature is too high.Adjust freezer controls. Freezer is recommended to
be approximately 0oF (-18oC)