Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Info
Service Diagnostics Setting permits you to determine the firmware and also software program variations, test standing of “design certain” system components as well as sensors, and also change state of elements where relevant (i.e.– compressor on/off, and so on.).
Enabling Service Mode: To allow Solution Mode, press and also hold the “WARMER” button while pushing the “COLDER” switch 4 times within five seconds.
- You can not enable Service Mode while in Establish Setting. – All system features will remain in their present state while in Service Setting.
- Alarm systems are handicapped during Service Mode as well as reset after leaving Service Mode.
- Solution Mode will instantly disable after five (5) mins of no keypad access
After getting in Service Setting, the very first number that you will certainly see shows the software program version number for the particular device you are servicing. For instance, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the very first number you will see is 11. See graph below for corresponding version as well as software referral.
The 2nd number you will certainly see suggests the software variation release. For instance, if you see 44 on the display screen panel it shows software application variation 4.4.
Diagnostics:
While in Service Setting, press the “COLLECTION” button to step via Tests 0-9. The initial figure of the display screen will reveal the examination number. The 2nd number suggests the existing state of each component under test and is presented as “1” being ON, CLOSED, or SHORTED as well as “0” being OFF or OPEN. Examinations 0 and 1 expose an open or shorted problem identified at the sensor inputs. Examinations 2 with 6 allow you to turn tons ON with the “WARMER” button as well as OFF with the “COLDER” button. Examinations 7 with 9 verify state modification of the door switches over and/or magnetic reed sensing unit. The component examinations readily available are explained in Offered Component Examinations chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Refrigerator runs too frequently | Doors have been opened frequently or has been opened for long periods of time | Reduce time door is open. Organize food items efficiently to assure door is open for shortest time |
Humidity levels too high Food has recently been added | Normal operation Allow time for added food to reach refrigerator or freezer temperature | |
freezer temperature freezer temperature freezer temperature | Evaluate refrigerator’s environment. Refrigerator environment. Refrigerator run more efficiently. | |
Condenser coils are dirty Controls need to be adjusted. Door is not closing properly | Clean coils. Adjust controls. Check for internal obstructions that are keeping door from closing properly. Refrigerator is not level. See installation instructions for details on how to level your refrigerator. Check gaskets for proper seal, clean if necessary |