Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Info
Solution Diagnostics Mode enables you to recognize the firmware as well as software program variations, examination status of “design specific” system parts and also sensing units, as well as alter state of components where appropriate (i.e.– compressor on/off, and so on.).
Enabling Solution Mode: To allow Solution Mode, press and hold the “WARMER” switch while pressing the “COLDER” switch four times within five seconds.
- You can not allow Solution Setting while in Set Mode. – All system functions will stay in their present state while in Service Setting.
- Alarm systems are disabled during Solution Setting and also reset after leaving Service Setting.
- Solution Mode will automatically disable after five (5) mins of no keypad entry
After entering Service Mode, the first number that you will see indicates the software program model number for the particular device you are servicing. For example, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the first number you will see is 11. See graph listed below for equivalent design and software reference.
The 2nd number you will certainly see shows the software variation launch. For instance, if you see 44 on the display screen panel it shows software application version 4.4.
Diagnostics:
While in Service Setting, press the “COLLECTION” button to tip through Tests 0-9. The very first digit of the display screen will certainly show the test number. The 2nd figure indicates the existing state of each element under test and also is shown as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Tests 0 and 1 reveal an open or shorted problem identified at the sensor inputs. Examinations 2 with 6 allow you to transform loads ON with the “WARMER” button as well as OFF with the “COLDER” button. Tests 7 through 9 verify state modification of the door switches over and/or magnetic reed sensor. The element examinations offered are defined in Offered Part Examinations chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Produce drawers do no close freely | Contents of drawer or positioning of items in compartments could be obstructing drawer. | Reposition food and containers to avoid interference with the drawers |
Drawer is not in proper position | Proper placement | |
Drawer channels are dirty or need treatment | Clean drawer channels with warm, soapy water. Rinse dry thoroughly. Apply thin layer of petroleum jelly to drawer channels |