Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Details
Service Diagnostics Mode allows you to recognize the firmware as well as software program versions, test status of “model particular” system components and sensors, and transform state of parts where relevant (i.e.– compressor on/off, etc.).
Enabling Service Mode: To allow Solution Setting, press and hold the “WARMER” button while pushing the “COLDER” switch four times within 5 secs.
- You can not make it possible for Solution Setting while in Establish Mode. – All system features will certainly stay in their existing state while in Service Setting.
- Alarm systems are impaired during Service Setting and reset after leaving Solution Mode.
- Solution Setting will immediately disable after five (5) mins of no keypad access
After getting in Solution Setting, the first number that you will see indicates the software program version number for the particular device you are servicing. For example, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the very first number you will see is 11. See graph below for corresponding design and software application recommendation.
The 2nd number you will see suggests the software program version release. As an example, if you see 44 on the display screen panel it shows software application variation 4.4.
Diagnostics:
While in Service Setting, press the “SET” button to tip through Tests 0-9. The very first figure of the display will certainly show the examination number. The 2nd number shows the existing state of each component under test and is shown as “1” being ON, CLOSED, or SHORTED as well as “0” being OFF or OPEN. Tests 0 and also 1 reveal an open or shorted condition found at the sensing unit inputs. Tests 2 through 6 enable you to transform loads ON with the “WARMER” switch as well as OFF with the “COLDER” button. Tests 7 via 9 confirm state change of the door changes and/or magnetic reed sensor. The component tests available are defined in Available Component Tests chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Produce drawers do no close freely | Contents of drawer or positioning of items in compartments could be obstructing drawer. | Reposition food and containers to avoid interference with the drawers |
Drawer is not in proper position | Proper placement | |
Drawer channels are dirty or need treatment | Clean drawer channels with warm, soapy water. Rinse dry thoroughly. Apply thin layer of petroleum jelly to drawer channels |