Thermador Rng-Stv-Ovn Codes – How to fix? by ApplianceRepairNewYork.us

THERMADOR Range/Stove/Oven Fault Codes beginning with an E. If an error apears in the cook setting home window.

Your stove is geared up with an incredibly trusted and also exact digital control. On the rare occasion that something happens that creates a breakdown, an error message will certainly appear in the oven selector home window. Some mistakes (E1, E9, E11, E12, as well as E13) needs to be gotten rid of by turning off the stove at the circuit breaker and then transforming it back on. When an error remains shown steadily in the off position, after trying to remove the error, a solution call is required. Have the mistake code offered when you require solution. This will help service determine the issue.

Error CodeNOTESCHECK/REPAIR
E1C,EControl board problem
E2K,GCook or clean mode runaway
E3A,HOpen oven temperature sensor (over 5000 ohms)
E4A,HShorted oven temperature sensor (under 500 ohms)
E5K,DControl board too cold or too hot, or defective board.
E6C,JControl board problem
E7A,IIllegal temp display turn off and retry
E8A,DControl board problem
E9A,ELatch switch problems
E10B,DControl board problem
E11A,FCT oven; latch switch problem
E12A,ECT oven; latch switch problem
E13A,CCT ovens; latch froze or no power to latch motor CMT ovens; control board not converted
E14A,ELatch switch problems
E15B,DControl board problem

Range/Stove/Oven Fault Codes Starting with F – How to fix? by HoustonAuthorizedRepair.com

ERROR CODENOTECHECK REPAIR
F0Internal logic failure; cancel key supervision. Sounds alarm and resets to non-cook modeReplace the electronic range control (also called clock or ERC)
F1Internal logic failure (monitoring function). Sounds alarm and inhibits cook modesReplace the electronic range control (also called clock or ERC)
F2Temperature runaway detected (Bake/Broil: 600 – 700 F; Clean: 930 – 1000 degrees F). Sounds alarm and resets to non-cook mode. Check relay board for stuck contacts. Check oven temperature sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check sensor wiring connectors for a loose or high resistance connection. Check electronic range control (also called clock or ERC) functionsReplace relay board if necessary. Replace oven temperature sensor if other components check normal. If failure repeats, replace electronic range control (also called clock or ERC)
F3Open circuit detected; oven temperature sensor. Check sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check wires and connections between electronic range control (also called clock or ERC) and oven temperature sensorReplace sensor if other components check normal. Replace electronic range control (also called clock or ERC) if fail code reoccurs
F4Short circuit detected; oven temperature sensor. Check sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check wires between electronic range control (also called clock or ERC) and sensor.Replace sensor if other components check normal. Replace electronic range control (also called clock or ERC) if fail code reoccurs
F7Function key shorted for over 16 seconds. Check for something pressing a key or preventing normal release of the keyReplace electronic range control (also called clock or ERC) if other components check normal
F8Internal logic failure; calibration. Alarm sounds and resets to non-cook mode. Check oven temperature sensor for normal room temperature resistance (1085-1097 ohms at 75 F). Check wires and connections between electronic range control (also called clock or ERC) and oven temperature sensorReplace electronic range control (also called clock or ERC) and oven temperature sensor if other components check normal
F9Internal logic ailure; door latch supervision. Alarm sounds and resets to non-cook mode. If door is locked due to clean temperatures, disconnect power until door can be unlockedReplace the electronic range control (also called clock or ERC)
FdBake & Broil relay drives active simultaneously. Check relay board for damage: trace E6 to K2 & K3, and burned contacts K3 & K3Replace electronic range control (also called clock or ERC). Replace relay board if necessary
Blank DisplayNo power to lectronic range control (also called clock or ERC). Check oven light and cooktop dial lights (powered by L2 & L1, respectively). Check relay board transformer primary, E1 to E2 (140 ohms typical). If the transformer internal fuse is still OK, check output voltages, pins 9 – 8 (3.2 v.a.c.) and 7 – 6 (21 v.a.c.). Check clock functions after replacing relay boardIf relay board transformer open (E1 to E2), replace relay board. If still no clock functions replace electronic range control (also called clock or ERC)