SubZero Refrigerator Freezer Error Code 07 – How to fix? by ApplianceRepairNewYork.us

Sub-Zero is the epitome of style as well as efficiency refrigeration. It isn’t simply an appliance, your Sub-Zero is an essential element of your excellent cooking area. It makes good sense that you wouldn’t wish to trust your fridge to just any kind of appliance repair service business. You desire a team of Sub-Zero fridge repair service specialists that can secure your investment while offering the premium service you should have.

It Is Fixed Device Repair is the company you need to rely on with every one of your Sub-Zero repair work needs. Our service technicians specialize in Sub-Zero service so you can trust that we have the skills to finish the job right.

HOW TO USE THE MISTAKE CODE TROUBLESHOOTING GUIDE

Mistake Codes indicate problems signed up by certain parts. If error codes are signed up, they will appear prior to temperature level analyses while in Diagnostic Setting.

NOTE: If Mistake Codes appear with a blinking “SERVICE” annunciator prior to initiating Diagnostic Setting, the system experienced too much compressor run problem that might or may not be associated with the Error Codes showed

To start Diagnostic Mode, press and hold either COLDER trick, after that push the POWER key, then release both tricks. Currently, inspect to see if Mistake Codes are present, being sure to toggle with all mistake and also temperature analyses by pressing either COLDER essential or either WARMER secret. (See Mistake Code Table Below).

If Error Codes appear throughout Diagnostic Setting, follow the Mistake Code Troubleshooting Guide on the adhering to page. The left column of the troubleshooting guide notes the mistake codes. The information in the ideal column explains what tests to carry out and/or what activity to require to correct the error.

KEEP IN MIND: If mistake codes are observed in analysis setting, a non-flashing SOLUTION annunciator will certainly show up on the LCD when Diagnostic Mode ends, showing error codes are still kept. Error Codes must be removed from the electronic control memory manually. To remove the non-flashing SERVICE annunciator and also the mistake codes, the trouble must be remedied and also the system must get on, then:.

  • On a model UC-24C: Press the Fridge Freezer WARMER and COLDER tricks for fifteen (15) secs.
  • On a version UC-24B, UC-24R, or UC-24RO: Press the Refrigerator WARMER and also COLDER secrets for fifteen (15) seconds.

Error Code Table

CODEINDICATION
05Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
06Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
07Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
08Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
20Defrost under-heat with no voltage feedback through Gray/White wire at defrost start
21Defrost overheat
22No voltage feedback through Gray/White wire at defrost start
23Defrost overheat with no voltage feedback through Gray/White wire at defrost start
24Defrost under-heat
30N/A
40Excessive Freezer Compressor Run
50Excessive Refrigerator Compressor Run
Error CodeCAUSESOLUTION
Error Code 07Inconsistent temperature readings in the refrigerator or freezer cabinet.The issue may be caused by loose or faulty connections between the thermistor and the control board, or it may mean the thermistor is faulty. Refer to your owner’s manual to locate the thermistor, and ensure the wires between the thermistor and control panel are securely connected. If you do not have your original manual, you may be able to find a digital copy online.

If the connections are secure, the thermistor and control panel will need to be tested to ensure functionality. Testing requires the use of a multimeter.

You may need the assistance of a specialist trained in Sub-Zero refrigerator repair to diagnose and replace the faulty components. 

Error Code 05.
A. If “EE” for refrigerator area was shown and also “SERVICE” flashing, examine the following:.

  1. Thermistor electric connections and also continuity from thermistor to J5 on control board. Reconnect/ fixing.
  2. Resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F( 0 ° C). Change if malfunctioning. B. If “EE” for fridge area was NOT presented, issue is intermittent thermistor mistake:.
  3. Door not closing properly. Right door closing problem.
  4. Examine light switch, circuitry & electrical links. Fixing circuitry/ links or replace button.
  5. Inspect thermistor electrical connections and connection at J5 on control board. Reconnect/ repair service.
  6. Check resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F (0 ° C). Replace if defective.
    C. If “EC 05” and also “SOLUTION” were flashing prior to initiating diagnostic setting, system also experienced excessive compressor run problem that might or may not be connected with the “05” Error Code. See Mistake Code 50 Test/Actions.